Smart
Sensor/Transmitter With Readout
|
Gas Detection For
Life
|
GD-K77D Series
|
 |
-
Digital display
with LCD back light
-
Sensor
information and calibration is stored within sensor memory
-
Several data
transmission options available Zero suppression and correction
-
Smaller housing
design for narrow wall mounting locations
-
Self-diagnostic
functions by microprocessor
-
Electrochemical
sensors for most semiconductor gases
-
Built-in
sampling pump
-
Easy replacement
of pump and sensor
-
Two alarm
levels, plus trouble alarm with relays
-
24VDC operation
-
Optional NEMA 4X
housing available
-
Semiconductor
-
Chemical
Processing
-
Laboratory
-
Manufacturing
|

|
The GD-K77D is a
complete sample drawing gas monitor, including digital readout and alarm
relays. A new gas sensor technology using an intelligent sensor for
remote location calibration and setup is used. The new GD-K77D sensors
are designed to provide a longer time period between calibrations.
Calibration intervals have been cut in half to12 months of on-line
service which equates to reduced maintenance cost. In addition, the
sensors can be calibrated away from the gas detector installation, for
example in a service area or offsite. This eliminates the inconvenience
of having calibration gases in the fab or monitoring location. GD-K77D
easily connects to an existing PLC system and is ideal for applications
needing a local readout or where a relay control is needed. |

|
Detection
Principle |
Electrochemical
cell |
|
Detection
Method |
Sample
drawing type |
|
Signal
Transmission |
Analog
transmission (4-20 mA)
Two wire digital transmission
|
|
Display |
Digital
LED display of gas concentration, 4 digits |
|
Gas
Alarms |
Two
alarm levels: 1st alarm (Yellow LED), 2nd alarm (Red LED) |
|
Dry
Outputs
For Remote
Alarms |
Dry
contact relay for 1st, 2nd, and trouble alarms (Normally Open or
Normally Closed) |
|
Alarm
Response Time |
Approximately
10 - 15 seconds when exposed to gas concentration of 1.6 times alarm
level for most gases (Same as T60) |
|
Self
Diagnosistic
Function |
Trouble,
low flow, system failure, communication error |
|
Operating
Conditions |
0
- 40*C, 30 - 85% R. H. |
|
Power
Requirements |
24
VDC |
|
Applicable
Cable |
Shielded
cable 3C, 1.25 sq (18 gauge)
Shielded twisted one pair cable, 1.25 sq (18 gauge)
|
|
Enclosure |
Wall
mounting |
|
Dimensions |
2.8"
(W) x 6.7" (H) x 6.0" (D), approximately 4.4 lbs
70 mm (W) x 170 mm (H) x 153 mm (D), approximately 2 kg
|

Partial
List Of Detectable Gases
Many other gases or ranges available. Contact RKI for gases or ranges not
listed
|
|
0 - 75.0 ppm |
|
Arsine
(AsH3 ) |
0 - 0.20 ppm |
|
Boron
Trichloride (BCl3) |
0
- 15.0 ppm |
|
Carbon
Dioxide (CO2) |
0
- 1.0 % |
|
Carbon
Monoxide (CO) |
0
- 300 ppm |
|
Chlorine
(Cl2) |
0
- 3.0 ppm |
|
Chlorine
Dioxide (ClO2) |
0
- 1.00 ppm |
|
Chlorine
Trifluoride (ClF3) |
0
- 1.00 ppm |
|
Combustibles |
0
-100% LEL |
|
Diborane
(B2H6) |
0
- 0.30 ppm |
|
Fluorine
(F2) |
0
- 6.0 ppm |
|
Hydrogen
(H2) |
0
- 2000 ppm |
|
Hydrogen
Chloride (HCl) |
0
- 15.0 ppm |
|
Hydrogen
Fluoride (HF) |
0
- 9.0 ppm |
|
Hydrogen
Sulfide (H2S) |
0
-100.0 ppm |
|
Nitric
Oxide (NO) |
0
-100.0 ppm |
|
Nitrogen
Dioxide (NO2) |
0
- 15.0 ppm |
|
Nitrogen
Trifluoride (NF3) |
0
- 30.0 ppm |
|
Oxygen
(O2) |
0
- 25.0 % |
|
Ozone
(O3) |
0
- 1.0 ppm |
|
Phosphine
(PH3) |
0
- 1.0 ppm |
|
Silane
(SiH4) |
0
- 15.0 ppm |
|
Sulfur
Dioxide (SO2) |
0
- 30.0 ppm |
|
TEOS
(Si(OC2H5)4) |
0
-15/30 ppm |
Specifications subject to
change without notice.
Made in the USA
|